{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-28T13:50:31.580","vulnerabilities":[{"cve":{"id":"CVE-2023-29463","sourceIdentifier":"PSIRT@rockwellautomation.com","published":"2023-09-12T17:15:09.147","lastModified":"2024-11-21T07:57:06.420","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nThe JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users’ session data and or log users out of their session.\n\n"},{"lang":"es","value":"La consola JMX dentro de Rockwell Automation Pavilion8 está expuesta a los usuarios de la aplicación y no requiere autenticación. Si se explota, un usuario malintencionado podría potencialmente recuperar los datos de sesión de otros usuarios de la aplicación o cerrar la sesión de los usuarios."}],"metrics":{"cvssMetricV31":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.5}]},"weaknesses":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","description":[{"lang":"en","value":"CWE-287"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-287"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:pavilion8:*:*:*:*:*:*:*:*","versionEndExcluding":"5.20","matchCriteriaId":"269FEE95-7517-453F-98E7-1D3B19ADF191"}]}]}],"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140590","source":"PSIRT@rockwellautomation.com","tags":["Permissions Required"]},{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140590","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Permissions Required"]}]}}]}