{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T17:42:47.879","vulnerabilities":[{"cve":{"id":"CVE-2023-2914","sourceIdentifier":"PSIRT@rockwellautomation.com","published":"2023-08-17T16:15:09.513","lastModified":"2024-11-21T07:59:33.587","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, an integer overflow condition exists in the affected products. When the ThinManager processes incoming messages, a read access violation occurs and terminates the process. A malicious user could exploit this vulnerability by sending a crafted synchronization protocol message and causing a denial of service condition in the software.  "}],"metrics":{"cvssMetricV31":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}]},"weaknesses":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","description":[{"lang":"en","value":"CWE-20"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-190"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*","versionStartIncluding":"11.0.0","versionEndIncluding":"11.0.6","matchCriteriaId":"6C40EF89-902D-40A0-9460-9C2037CDAF45"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*","versionStartIncluding":"11.1.0","versionEndIncluding":"11.1.6","matchCriteriaId":"DCB9F021-2307-4183-A6B8-CAEE88808C92"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*","versionStartIncluding":"11.2.0","versionEndIncluding":"11.2.7","matchCriteriaId":"A8C2E2BF-3ABA-4E69-9A8F-4E2AC6C48E2E"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*","versionStartIncluding":"12.0.0","versionEndIncluding":"12.0.5","matchCriteriaId":"66054D47-416A-4194-9B95-AE810924AD94"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*","versionStartIncluding":"12.1.0","versionEndIncluding":"12.1.6","matchCriteriaId":"3AAE89B3-6C25-4DE7-898A-2F8637122B01"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*","versionStartIncluding":"13.0.0","versionEndIncluding":"13.0.2","matchCriteriaId":"A5D9F5DA-D66A-4F88-A1C4-E1411715162F"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:13.1.0:*:*:*:*:*:*:*","matchCriteriaId":"DE7FC8D4-F5EF-45DC-9D95-4CFBC3FE1E3B"}]}]}],"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140471","source":"PSIRT@rockwellautomation.com","tags":["Permissions Required"]},{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140471","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Permissions Required"]}]}}]}