{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T00:40:18.367","vulnerabilities":[{"cve":{"id":"CVE-2023-2746","sourceIdentifier":"PSIRT@rockwellautomation.com","published":"2023-07-11T14:15:09.467","lastModified":"2024-11-21T07:59:12.863","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"The Rockwell Automation Enhanced HIM software contains \n\nan API that the application uses that is not protected sufficiently and uses incorrect Cross-Origin Resource Sharing (CORS) settings and, as a result, is vulnerable to a Cross Site Request Forgery (CSRF) attack. To exploit this vulnerability, a malicious user would have to convince a user to click on an untrusted link through a social engineering attack or successfully perform a Cross Site Scripting Attack (XSS). Exploitation of a CSRF could potentially lead to sensitive information disclosure and full remote access to the affected products.\n\n\n\n\n"}],"metrics":{"cvssMetricV31":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H","baseScore":9.6,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H","baseScore":9.6,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":6.0}]},"weaknesses":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","description":[{"lang":"en","value":"CWE-352"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-352"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:enhanced_him:1.001:*:*:*:*:*:*:*","matchCriteriaId":"51135134-B184-4E8E-8B1E-9D3B58F5E0C2"}]}]}],"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139760","source":"PSIRT@rockwellautomation.com","tags":["Permissions Required","Vendor Advisory"]},{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139760","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Permissions Required","Vendor Advisory"]}]}}]}