{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T14:03:14.706","vulnerabilities":[{"cve":{"id":"CVE-2023-25620","sourceIdentifier":"cybersecurity@se.com","published":"2023-04-19T09:15:07.457","lastModified":"2024-11-21T07:49:50.757","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\n\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when a malicious project file is loaded onto the\ncontroller by an authenticated user. \n\n \n\n"}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":3.6}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-754"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.10","matchCriteriaId":"C4818276-B0D9-41F6-B8F6-C94B88F6E2A1"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*","matchCriteriaId":"E876C738-ABF6-4864-98A6-1E06E96A0DF4"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.51","matchCriteriaId":"DDBE606F-EE13-410F-839A-708EB480B3E3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*","matchCriteriaId":"138681A2-0146-492B-8E10-06849FC27C6E"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_momentum_unity_m1e_processor_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"C53AFB8E-0830-46BE-8BED-4BF61B354262"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_momentum_unity_m1e_processor:-:*:*:*:*:*:*:*","matchCriteriaId":"6C0178B3-FC32-4473-A368-A614F6F55F98"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_mc80_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"526DCF0E-C625-4114-80CB-AD79912104FF"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_mc80:-:*:*:*:*:*:*:*","matchCriteriaId":"B7A6BC87-E598-4DB6-AD19-5E836C1B6570"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:140cpu65_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"12B6D628-61AA-4999-B71F-FF93182A035B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:140cpu65:-:*:*:*:*:*:*:*","matchCriteriaId":"F6E9922C-D583-4820-9BAC-8D8CC31F482B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:tsxp57_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"B20CF298-0E3F-4142-B7CF-791FA5E5545C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:tsxp57:-:*:*:*:*:*:*:*","matchCriteriaId":"D2161791-5948-4C6E-B0FC-8DC7686CD87A"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:bmep58s_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"24D21387-44D7-49C3-A809-85AF4D221772"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:bmep58s:-:*:*:*:*:*:*:*","matchCriteriaId":"7C1E042E-5DF3-4C78-95AC-114AB889A7E7"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:bmeh58s_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"10BD4983-0194-4499-A6F8-6FD123482F33"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:bmeh58s:-:*:*:*:*:*:*:*","matchCriteriaId":"0E6CCDB6-CAFB-49CB-AB5B-EDDC13835F03"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-05.pdf","source":"cybersecurity@se.com"},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-05.pdf","source":"af854a3a-2127-422b-91ae-364da2661108"}]}}]}