{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-01T12:06:45.220","vulnerabilities":[{"cve":{"id":"CVE-2023-2263","sourceIdentifier":"PSIRT@rockwellautomation.com","published":"2023-07-18T16:15:11.600","lastModified":"2024-11-21T07:58:15.953","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nThe Rockwell Automation Kinetix 5700 DC Bus Power Supply Series A is vulnerable to CIP fuzzing.  The new ENIP connections cannot be established if impacted by this vulnerability,  which prohibits operational capabilities of the device resulting in a denial-of-service attack.\n\n\n"}],"metrics":{"cvssMetricV31":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}]},"weaknesses":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","description":[{"lang":"en","value":"CWE-400"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-400"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:kinetix_5700_firmware:13.001:*:*:*:*:*:*:*","matchCriteriaId":"267EEFBB-3FA0-4ADB-B70A-28BDA408C77A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:kinetix_5700:series_a:*:*:*:*:*:*:*","matchCriteriaId":"7676D1CF-FC31-482C-A348-4FCF4FBAAEE3"}]}]}],"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140029","source":"PSIRT@rockwellautomation.com","tags":["Permissions Required","Vendor Advisory"]},{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140029","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Permissions Required","Vendor Advisory"]}]}}]}