{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-09T11:17:29.826","vulnerabilities":[{"cve":{"id":"CVE-2023-1285","sourceIdentifier":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","published":"2023-04-14T03:15:07.003","lastModified":"2024-11-21T07:38:49.580","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Signal Handler Race Condition vulnerability in Mitsubishi Electric India GC-ENET-COM whose first 2 digits of 11-digit serial number of unit are \"16\" allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in Ethernet communication by sending a large number of specially crafted packets to any UDP port when GC-ENET-COM is configured as a Modbus TCP Server. The communication resumes only when the power of the main unit is turned off and on or when the GC-ENET-COM is hot-swapped from the main unit.\n"}],"metrics":{"cvssMetricV31":[{"source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":5.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.2,"impactScore":3.6}]},"weaknesses":[{"source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","type":"Secondary","description":[{"lang":"en","value":"CWE-364"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-362"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:mitsubishielectric:gc-enet-com_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"0A0AA732-9C55-45CA-A049-5D8BC40926A5"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:mitsubishielectric:gc-enet-com:-:*:*:*:*:*:*:*","matchCriteriaId":"FB5D1352-A15E-43A5-9CF7-374E4DA7A080"}]}]}],"references":[{"url":"https://mitsubishielectric.in/fa/cnc-pdf/DoS_in_Ethernet_Communication_Extension_Unit_GC_ENET_COM_of_GOC35_Series.pdf","source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","tags":["Vendor Advisory"]},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-15","source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://mitsubishielectric.in/fa/cnc-pdf/DoS_in_Ethernet_Communication_Extension_Unit_GC_ENET_COM_of_GOC35_Series.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-15","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}