{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-06T14:38:38.403","vulnerabilities":[{"cve":{"id":"CVE-2022-47936","sourceIdentifier":"productcert@siemens.com","published":"2023-02-14T11:15:14.473","lastModified":"2024-11-21T07:32:34.637","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:jt_open_toolkit:*:*:*:*:*:*:*:*","versionEndExcluding":"11.2.3.0","matchCriteriaId":"33C7875E-FA42-4163-9395-B5A06E698328"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:jt_utilities:*:*:*:*:*:*:*:*","versionEndExcluding":"11.2.3.0","matchCriteriaId":"7300A3A0-744A-4D5A-A1CD-D83A1FE97A0B"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"34.0","versionEndExcluding":"34.0.252","matchCriteriaId":"F0D9079D-6138-4602-A982-9BC4ECBC35E7"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"34.1","versionEndExcluding":"34.1.242","matchCriteriaId":"4C486991-A1C0-4815-AAD6-163464D711AA"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"35.0","versionEndExcluding":"35.0.170","matchCriteriaId":"EA2114FD-BB07-4C24-98B1-928A510565BB"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"35.1","versionEndExcluding":"35.1.150","matchCriteriaId":"5C98612B-63DF-473C-AF6E-CF3740356D5B"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}