{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-20T09:30:24.675","vulnerabilities":[{"cve":{"id":"CVE-2022-46345","sourceIdentifier":"productcert@siemens.com","published":"2022-12-13T16:15:25.330","lastModified":"2024-11-21T07:30:25.770","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)"},{"lang":"es","value":"Se ha identificado una vulnerabilidad en: \nParasolid V33.1 (Todas las versiones &lt; V33.1.264), \nParasolid V34.0 (Todas las versiones &lt; V34.0.252), \nParasolid V34.1 (Todas las versiones &lt; V34.1.242), \nParasolid V35 .0 (Todas las versiones &lt; V35.0.170), \nSolid Edge SE2022 (Todas las versiones &lt; V222.0MP12), \nSolid Edge SE2022 (Todas las versiones), \nSolid Edge SE2023 (Todas las versiones &lt; V223.0Update2). \nLas aplicaciones afectadas contienen una escritura fuera de los límites más allá del final de una estructura asignada mientras analizan archivos X_B especialmente manipulados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual. (ZDI-CAN-19070)"}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]},{"source":"nvd@nist.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"33.1","versionEndExcluding":"33.1.264","matchCriteriaId":"F1405366-A402-4908-858D-E844853BE1DA"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"34.0","versionEndExcluding":"34.0.252","matchCriteriaId":"F0D9079D-6138-4602-A982-9BC4ECBC35E7"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"34.1","versionEndExcluding":"34.1.242","matchCriteriaId":"4C486991-A1C0-4815-AAD6-163464D711AA"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"35.0","versionEndExcluding":"35.0.170","matchCriteriaId":"EA2114FD-BB07-4C24-98B1-928A510565BB"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge_se2022:*:*:*:*:*:*:*:*","matchCriteriaId":"6FF17E24-2697-4110-8A0F-BC76BA617C76"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge_se2023:-:*:*:*:*:*:*:*","matchCriteriaId":"60B92DC2-5A0D-4F6E-81FD-3A0CA25B0D32"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*","matchCriteriaId":"E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}