{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-06T08:45:04.263","vulnerabilities":[{"cve":{"id":"CVE-2022-45098","sourceIdentifier":"security_alert@emc.com","published":"2023-02-01T06:15:08.883","lastModified":"2024-11-21T07:28:46.703","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nDell PowerScale OneFS, 9.0.0.x-9.4.0.x, contain a cleartext storage of sensitive information vulnerability in S3 component. An authenticated local attacker could potentially exploit this vulnerability, leading to information disclosure.\n\n\n\n\n\n"}],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:L/A:L","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":1.3,"impactScore":4.7},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","baseScore":5.5,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":1.8,"impactScore":3.6}]},"weaknesses":[{"source":"security_alert@emc.com","type":"Secondary","description":[{"lang":"en","value":"CWE-532"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-312"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*","versionStartIncluding":"9.1.0.0","versionEndExcluding":"9.1.0.25","matchCriteriaId":"5B70E157-0469-4AFC-AEA0-9772934655C1"},{"vulnerable":true,"criteria":"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*","versionStartIncluding":"9.2.1.0","versionEndExcluding":"9.2.1.18","matchCriteriaId":"FB381CD3-FEC0-44D7-A011-070575ECB27B"},{"vulnerable":true,"criteria":"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*","versionStartIncluding":"9.4.0.0","versionEndExcluding":"9.4.0.9","matchCriteriaId":"703052FC-339D-4BE6-A549-96B5AFF27DB1"}]}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000206357/dell-emc-powerscale-onefs-security-updates-for-multiple-security-vulnerabilities","source":"security_alert@emc.com","tags":["Vendor Advisory"]},{"url":"https://www.dell.com/support/kbdoc/en-us/000206357/dell-emc-powerscale-onefs-security-updates-for-multiple-security-vulnerabilities","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}