{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-11T20:45:28.612","vulnerabilities":[{"cve":{"id":"CVE-2022-45094","sourceIdentifier":"productcert@siemens.com","published":"2023-01-10T12:15:23.590","lastModified":"2024-11-21T07:28:46.187","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially inject commands into the dhcpd configuration of the affected product. An attacker might leverage this to trigger remote code execution on the affected component."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SINEC INS (Todas las versiones "}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","baseScore":8.4,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.7,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-77"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0","matchCriteriaId":"C89891C1-DFD7-4E1F-80A9-7485D86A15B5"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*","matchCriteriaId":"4664B195-AF14-4834-82B3-0B2C98020EB6"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*","matchCriteriaId":"75BC588E-CDF0-404E-AD61-02093A1DF343"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*","matchCriteriaId":"A334F7B4-7283-4453-BAED-D2E01B7F8A6E"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}