{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-07T17:17:59.681","vulnerabilities":[{"cve":{"id":"CVE-2022-44457","sourceIdentifier":"productcert@siemens.com","published":"2022-11-08T11:15:12.257","lastModified":"2025-05-01T18:15:50.063","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.0 < V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.1 < V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Mendix SAML (compatible con Mendix 7) (Todas las versiones &lt; V1.17.0),\nMendix SAML (compatible con Mendix 7) (Todas las versiones &gt;= V1.17.0 &lt; V1.17.2), \nMendix SAML (Mendix 8 compatible) (Todas las versiones &lt; V2.3.0), \nMendix SAML (compatible con Mendix 8) (Todas las versiones &gt; V2.3.0 &lt; V2.3.2), \nMendix SAML (compatible con Mendix 9, New Track) (Todas las versiones &lt;  V3.3.1), \nMendix SAML (compatible con Mendix 9, New Track) (todas las versiones &gt;= V3.3.1 &lt; V3.3.5), \nMendix SAML (compatible con Mendix 9, Upgrade Track) (todas las versiones &lt; V3.3.0 ), \nMendix SAML (compatible con Mendix 9, Upgrade Track) (Todas las versiones &gt; V3.3.0  y &lt; V3.3.4). \nLas versiones afectadas del módulo no protegen suficientemente contra la reproducción de captura de paquetes, solo cuando la opción de configuración no predeterminada y no recomendada \"\"Permitir Autenticación Iniciada por Idp\"\" está habilitada. Esta entrada de CVE describe la solución incompleta para CVE-2022-37011 en una configuración específica no predeterminada."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-294"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-294"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*","versionEndExcluding":"1.17.0","matchCriteriaId":"FAE0D810-0D2A-4158-B1A1-045743098BA9"},{"vulnerable":true,"criteria":"cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*","versionStartIncluding":"2.3.0","versionEndExcluding":"2.3.2","matchCriteriaId":"6C2A31D3-792D-46F1-90C3-818EEE5D1C1B"},{"vulnerable":true,"criteria":"cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*","versionStartIncluding":"3.3.0","versionEndExcluding":"3.3.4","matchCriteriaId":"083B7407-2BCC-41DC-BF2D-2AC3298A7FAA"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}