{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-08-04T22:00:53.539","vulnerabilities":[{"cve":{"id":"CVE-2022-43933","sourceIdentifier":"sirt@brocade.com","published":"2024-11-21T11:15:11.077","lastModified":"2026-06-17T05:07:30.240","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"An information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where configuration secrets are logged in supportsave. Supportsave file is generated by an admin user troubleshooting the switch. The Logged information may include usernames and passwords, and secret keys."},{"lang":"es","value":"Existe una vulnerabilidad de exposición de información a través de un archivo de registro en Brocade SANnav anterior a Brocade SANnav 2.2.2, donde los secretos de configuración se registran en supportsave. El archivo supportsave lo genera un usuario administrador que soluciona problemas en el conmutador. La información registrada puede incluir nombres de usuario, contraseñas y claves secretas."}],"affected":[{"source":"sirt@brocade.com","affectedData":[{"vendor":"Brocade","product":"SANnav","defaultStatus":"unaffected","versions":[{"version":"before Brocade SANnav 2.2.2","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"sirt@brocade.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","baseScore":4.4,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":0.8,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","baseScore":4.4,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":0.8,"impactScore":3.6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2024-11-21T17:55:44.908275Z","id":"CVE-2022-43933","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"sirt@brocade.com","type":"Secondary","description":[{"lang":"en","value":"CWE-538"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-532"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*","versionEndExcluding":"2.2.2","matchCriteriaId":"DC77C573-F6AD-451A-B543-682C9276861D"}]}]}],"references":[{"url":"https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/21221","source":"sirt@brocade.com","tags":["Vendor Advisory"]}]}}]}