{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-25T14:43:11.702","vulnerabilities":[{"cve":{"id":"CVE-2022-43259","sourceIdentifier":"cve@mitre.org","published":"2022-10-18T15:15:10.390","lastModified":"2026-06-17T05:06:10.000","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Tenda AC15 V15.03.05.18 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function."},{"lang":"es","value":"Se ha detectado que Tenda AC15 versión V15.03.05.18, contiene un desbordamiento de pila por medio del parámetro timeZone en la función form_fast_setting_wifi_set"}],"affected":[{"source":"cve@mitre.org","affectedData":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-05-12T14:47:53.325013Z","id":"CVE-2022-43259","options":[{"exploitation":"poc"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*","matchCriteriaId":"56881C41-A993-45CC-BAE6-E9DE17FA56E2"},{"vulnerable":true,"criteria":"cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*","matchCriteriaId":"A14A19EE-FB4E-4371-AC85-1401EB78B16D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*","matchCriteriaId":"B73E7C1C-F121-486A-8B15-E97EA0C219A5"}]}]}],"references":[{"url":"https://drive.google.com/file/d/1VjYjZKv7MJ69hGPG-xD0xublUw-taq4w/view?usp=sharing","source":"cve@mitre.org","tags":["Exploit","Third Party Advisory"]},{"url":"https://drive.google.com/file/d/1VjYjZKv7MJ69hGPG-xD0xublUw-taq4w/view?usp=sharing","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}}]}