{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T18:23:11.700","vulnerabilities":[{"cve":{"id":"CVE-2022-42891","sourceIdentifier":"productcert@siemens.com","published":"2022-11-17T17:15:12.577","lastModified":"2025-04-29T20:15:21.857","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website’s application pool."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en syngo Dynamics (todas las versiones &lt; VA40G HF01). El servidor de aplicaciones syngo Dynamics aloja un servicio web mediante una operación con control de acceso de escritura inadecuado que podría permitir escribir datos en cualquier carpeta accesible a la cuenta asignada al grupo de aplicaciones del sitio web."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-73"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-610"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:syngo_dynamics_cardiovascular_imaging_and_information_system:*:*:*:*:*:*:*:*","versionEndExcluding":"va40g_hf01","matchCriteriaId":"B2F3FBF4-8431-4C9D-8173-CA6DEC1104F0"}]}]}],"references":[{"url":"https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}