{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-09T11:36:01.303","vulnerabilities":[{"cve":{"id":"CVE-2022-41670","sourceIdentifier":"cybersecurity@se.com","published":"2022-11-04T14:15:10.627","lastModified":"2024-11-21T07:23:36.567","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior)."},{"lang":"es","value":"Existe una vulnerabilidad CWE-22: Limitación Inadecuada de un Nombre de Ruta a un Directorio Restringido (\"Path Traversal\") en el componente SGIUtility que permite a adversarios con privilegios de usuario local cargar archivos DLL maliciosos que podrían resultar en la ejecución de código malicioso. Productos afectados: EcoStruxure Operator Terminal Expert (V3.3 Hotfix 1 o anterior), Pro-face BLUE (V3.3 Hotfix 1 o anterior)."}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.0,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.0,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-22"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*","versionEndExcluding":"3.3","matchCriteriaId":"5705916B-E189-4314-AD32-C8D42991DFA2"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:-:*:*:*:*:*:*","matchCriteriaId":"A6EAEC62-F689-43A2-8EDB-68867661ED92"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:hotfix1:*:*:*:*:*:*","matchCriteriaId":"54A2C97D-9FE0-4E01-B9BE-D5508CFEEB5A"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:pro-face_blue:*:*:*:*:*:*:*:*","versionEndExcluding":"3.3","matchCriteriaId":"297C4149-AA1F-4033-BD74-0FB908783399"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:pro-face_blue:3.3:-:*:*:*:*:*:*","matchCriteriaId":"FB229476-7E0C-46ED-817D-C9A72250CC5D"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:pro-face_blue:3.3:hotfix1:*:*:*:*:*:*","matchCriteriaId":"C893D88A-656A-4748-841C-5851D34E9C69"}]}]}],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2022-284-01/","source":"cybersecurity@se.com","tags":["Patch","Vendor Advisory"]},{"url":"https://www.se.com/ww/en/download/document/SEVD-2022-284-01/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}