{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-16T11:49:00.798","vulnerabilities":[{"cve":{"id":"CVE-2022-41302","sourceIdentifier":"psirt@autodesk.com","published":"2022-10-14T17:15:16.100","lastModified":"2025-05-14T16:15:22.247","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An Out-Of-Bounds Read Vulnerability in Autodesk FBX SDK version 2020. and prior may lead to code execution or information disclosure through maliciously crafted FBX files. This vulnerability in conjunction with other vulnerabilities could lead to code execution in the context of the current process."},{"lang":"es","value":"Una vulnerabilidad de lectura fuera de límites en Autodesk FBX SDK versión 2020. y anteriores puede conllevar a una ejecución de código o una divulgación de información mediante archivos FBX diseñados de forma maliciosa. Esta vulnerabilidad, junto con otras, podría conllevar a una ejecución de código en el contexto del proceso actual"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-125"}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-125"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:autodesk:fbx_software_development_kit:2020.0:*:*:*:*:*:*:*","matchCriteriaId":"8805EE28-F361-482B-81FC-4E31F2EDB85D"}]}]}],"references":[{"url":"https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0022","source":"psirt@autodesk.com","tags":["Patch","Vendor Advisory"]},{"url":"https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0022","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}