{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T20:21:36.998","vulnerabilities":[{"cve":{"id":"CVE-2022-41283","sourceIdentifier":"productcert@siemens.com","published":"2022-12-13T16:15:22.697","lastModified":"2024-11-21T07:22:58.570","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains an out of bounds write vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en:\nJT2Go (Todas las versiones &lt; V14.1.0.6), \nTeamcenter Visualization V13.2 (Todas las versiones &lt; V13.2.0.12), \nTeamcenter Visualization V13.3 (Todas las versiones &lt; V13.3.0. 8), \nTeamcenter Visualization V14.0 (todas las versiones &lt; V14.0.0.4), \nTeamcenter Visualization V14.1 (todas las versiones &lt; V14.1.0.6). \nCGM_NIST_Loader.dll contiene una vulnerabilidad de escritura fuera de los límites al analizar un archivo CGM. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual."}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]},{"source":"nvd@nist.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:jt2go:-:*:*:*:*:*:*:*","matchCriteriaId":"A264819D-B571-4E10-98CE-7D1E2C04D312"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"13.2.0","versionEndExcluding":"13.2.0.12","matchCriteriaId":"2CB3887E-4564-4715-B27F-5BE6757EE960"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"13.3.0","versionEndExcluding":"13.3.0.8","matchCriteriaId":"DF82E5C7-68B6-456B-9658-CCF1FB1DC4D9"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"14.0","versionEndExcluding":"14.0.0.4","matchCriteriaId":"B0296066-2DC4-407F-9AA9-49BE916988C8"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"14.1","versionEndExcluding":"14.1.0.6","matchCriteriaId":"D8922308-85AE-4EAE-BF4A-7CE54201713B"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}