{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-16T21:43:02.631","vulnerabilities":[{"cve":{"id":"CVE-2022-40656","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2022-09-15T16:15:12.317","lastModified":"2025-04-10T20:51:02.880","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"This vulnerability allows remote attackers to execute arbitrary code on affected installations of NIKON NIS-Elements Viewer 13.2.0.21165. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ND2 files. Crafted data in a ND2 file can trigger a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15072."},{"lang":"es","value":"Esta vulnerabilidad permite a atacantes remotos ejecutar código arbitrario en las instalaciones afectadas de NIKON NIS-Elements Viewer 13.2.0.21165. Es requerida una interacción del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una página maliciosa o abrir un archivo malicioso. El fallo específico se presenta en el análisis de los archivos ND2. Los datos diseñados en un archivo ND2 pueden desencadenar una lectura más allá del final de un búfer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual. Era ZDI-CAN-15072"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-125"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-125"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:nikon:nis-elements_viewer:13.2.0.21165:*:*:*:*:*:*:*","matchCriteriaId":"13216A09-8CB8-48D4-ACE9-97081B3B7AFA"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-1212/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.software-dl.microscope.healthcare.nikon.com/vuln/index.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.software-dl.microscope.healthcare.nikon.com/vuln/pdf/Vulnerabilities_on_NIS-Elements_Freeware_and_L_en_240917_02.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-1212/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}