{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T04:25:47.266","vulnerabilities":[{"cve":{"id":"CVE-2022-39067","sourceIdentifier":"psirt@zte.com.cn","published":"2022-11-22T17:15:10.373","lastModified":"2025-04-29T05:15:42.870","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"There is a buffer overflow vulnerability in ZTE MF286R. Due to lack of input validation on parameters of the wifi interface, an authenticated attacker could use the vulnerability to perform a denial of service attack."},{"lang":"es","value":"Hay una vulnerabilidad de desbordamiento del búfer en ZTE MF286R. Debido a la falta de validación de entrada en los parámetros de la interfaz wifi, un atacante autenticado podría utilizar la vulnerabilidad para realizar un ataque de Denegación de Servicio (DoS)."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":3.6},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":3.6}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-120"}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-120"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:zte:mf286r_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"mf286r_b07","matchCriteriaId":"DB83FA9E-1DE1-4200-83BB-42F48869CDAB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:zte:mf286r:-:*:*:*:*:*:*:*","matchCriteriaId":"6AF5C7D2-70E8-4E1C-B712-7F9A026EAEC8"}]}]}],"references":[{"url":"https://support.zte.com.cn/support/news/LoopholeInfoDetail.aspx?newsId=1027784","source":"psirt@zte.com.cn","tags":["Vendor Advisory"]},{"url":"https://support.zte.com.cn/support/news/LoopholeInfoDetail.aspx?newsId=1027784","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}