{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T15:51:44.880","vulnerabilities":[{"cve":{"id":"CVE-2022-37011","sourceIdentifier":"productcert@siemens.com","published":"2022-09-13T10:15:10.763","lastModified":"2024-11-21T07:14:16.827","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0). Affected versions of the module insufficiently protect from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. For compatibility reasons, fix versions still contain this issue, but only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en el módulo SAML de Mendix (compatible con Mendix 7) (todas las versiones anteriores a V1.17.0), el módulo SAML de Mendix (compatible con Mendix 8) (todas las versiones anteriores a V2.3.0), el módulo SAML de Mendix (compatible con Mendix 9, New Track) (todas las versiones anteriores a V3.3.1), el módulo SAML de Mendix (compatible con Mendix 9, Upgrade Track) (todas las versiones anteriores a V3.3.0). Las versiones afectadas del módulo no protegen suficientemente de la repetición de la captura de paquetes. Esto podría permitir a atacantes remotos no autorizados eludir la autenticación y obtener acceso a la aplicación. Por razones de compatibilidad, las versiones corregidas aún contienen este problema, pero sólo cuando la opción de configuración no recomendada y no predeterminada `'Permitir autenticación iniciada por Idp'` está activada"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-294"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*","versionEndExcluding":"1.17.0","matchCriteriaId":"FAE0D810-0D2A-4158-B1A1-045743098BA9"},{"vulnerable":true,"criteria":"cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*","versionStartIncluding":"2.0.0","versionEndExcluding":"2.3.0","matchCriteriaId":"C78D80C0-D12B-41C8-BEA8-576BF2FC5A31"},{"vulnerable":true,"criteria":"cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*","versionStartIncluding":"3.0.0","versionEndExcluding":"3.3.1","matchCriteriaId":"22874B0C-7AF0-4223-9116-7AF3F6A38A32"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf","source":"productcert@siemens.com","tags":["Patch","Third Party Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Third Party Advisory"]}]}}]}