{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-20T18:59:36.298","vulnerabilities":[{"cve":{"id":"CVE-2022-3686","sourceIdentifier":"cybersecurity@hitachienergy.com","published":"2023-03-28T13:15:07.007","lastModified":"2024-11-21T07:20:01.947","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability exists in a SDM600 endpoint.\nAn attacker could exploit this vulnerability by running multiple parallel requests, the SDM600 web services become busy rendering the application unresponsive.\nThis issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291)\n\n \n\nList of CPEs:\n\n\n  *  cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*\n\n\n"}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@hitachienergy.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L","baseScore":4.8,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":2.2,"impactScore":2.5},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","baseScore":9.1,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":5.2}]},"weaknesses":[{"source":"cybersecurity@hitachienergy.com","type":"Secondary","description":[{"lang":"en","value":"CWE-285"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-Other"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:hitachienergy:sdm600:*:*:*:*:*:*:*:*","versionStartIncluding":"1.0","versionEndExcluding":"1.2.23000.291","matchCriteriaId":"49AC31BD-3956-473C-9D1C-CB02FA730D00"}]}]}],"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000138&LanguageCode=en&DocumentPartId=&Action=Launch","source":"cybersecurity@hitachienergy.com","tags":["Vendor Advisory"]},{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000138&LanguageCode=en&DocumentPartId=&Action=Launch","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}