{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-07-02T09:32:16.348","vulnerabilities":[{"cve":{"id":"CVE-2022-35872","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2022-07-25T19:15:46.600","lastModified":"2026-06-17T04:52:25.880","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17115."},{"lang":"es","value":"Esta vulnerabilidad permite a atacantes remotos ejecutar código arbitrario en las instalaciones afectadas de Inductive Automation Ignition versión 8.1.15 (b2022030114). Es requerida la interacción del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una página maliciosa o abrir un archivo malicioso. El fallo específico se presenta en el análisis de archivos ZIP. El problema es debido a una falta de comprobación apropiada de los datos suministrados por el usuario, lo que puede resultar en una deserialización de datos no confiables. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto de SYSTEM. Era ZDI-CAN-17115"}],"affected":[{"source":"zdi-disclosures@trendmicro.com","affectedData":[{"vendor":"Inductive Automation","product":"Ignition","versions":[{"version":"8.1.15 (b2022030114)","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-502"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:inductiveautomation:ignition:8.1.15:*:*:*:*:*:*:*","matchCriteriaId":"56460FC6-B26E-4945-BBC9-6F382CFB0DDB"}]}]}],"references":[{"url":"https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities","source":"zdi-disclosures@trendmicro.com","tags":["Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-1019/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-1019/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}