{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-01T21:18:07.974","vulnerabilities":[{"cve":{"id":"CVE-2022-34383","sourceIdentifier":"security_alert@emc.com","published":"2022-08-31T20:15:08.747","lastModified":"2024-11-21T07:09:24.340","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Dell Edge Gateway 5200 (EGW) versions before 1.03.10 contain an operating system command injection vulnerability. A local malicious user may potentially exploit this vulnerability by using an SMI to bypass PMC mitigation and gain arbitrary code execution during SMM."},{"lang":"es","value":"Dell Edge Gateway 5200 (EGW) versiones anteriores a 1.03.10, contienen una vulnerabilidad de inyección de comandos en el sistema operativo. Un usuario local malicioso puede explotar potencialmente esta vulnerabilidad al usar un SMI para omitir la mitigación del PMC y conseguir una ejecución de código arbitrario durante el SMM"}],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:L","baseScore":8.1,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"LOW"},"exploitabilityScore":1.5,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","baseScore":8.2,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.5,"impactScore":6.0}]},"weaknesses":[{"source":"security_alert@emc.com","type":"Secondary","description":[{"lang":"en","value":"CWE-77"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:dell:edge_gateway_5200_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.03.10","matchCriteriaId":"D017E208-1233-450E-AA08-0273D6A98916"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:dell:edge_gateway_5200:-:*:*:*:*:*:*:*","matchCriteriaId":"F6832A53-E950-4572-A178-CF5DC14CACC5"}]}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000202711","source":"security_alert@emc.com","tags":["Patch","Vendor Advisory"]},{"url":"https://www.dell.com/support/kbdoc/en-us/000202711","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}