{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-27T18:28:40.305","vulnerabilities":[{"cve":{"id":"CVE-2022-33202","sourceIdentifier":"vultures@jpcert.or.jp","published":"2022-06-27T01:15:07.340","lastModified":"2024-11-21T07:07:42.470","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Authentication bypass vulnerability in the setup screen of L2Blocker(on-premise) Ver4.8.5 and earlier and L2Blocker(Cloud) Ver4.8.5 and earlier allows an adjacent attacker to perform an unauthorized login and obtain the stored information or cause a malfunction of the device by using alternative paths or channels for Sensor."},{"lang":"es","value":"Una vulnerabilidad de evasión de autenticación en la pantalla de configuración de L2Blocker(on-premise) versiones Ver4.8.5 y anteriores y L2Blocker(Cloud) versiones Ver4.8.5 y anteriores, permite a un atacante adyacente llevar a cabo un inicio de sesión no autorizado y obtener la información almacenada o causar un mal funcionamiento del dispositivo mediante el uso de rutas o canales alternativos para el Sensor"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","baseScore":8.1,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":5.2}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:A/AC:L/Au:N/C:P/I:P/A:N","baseScore":4.8,"accessVector":"ADJACENT_NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":6.5,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-287"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:softcreate:l2blocker:*:*:*:*:cloud:*:*:*","versionEndExcluding":"4.8.6","matchCriteriaId":"77FDDA78-F607-4012-8ED6-8BC2D9F72ACC"},{"vulnerable":true,"criteria":"cpe:2.3:a:softcreate:l2blocker:*:*:*:*:on-premise:*:*:*","versionEndExcluding":"4.8.6","matchCriteriaId":"99E6A5D4-21D8-46BE-A563-C56D631A3172"}]}]}],"references":[{"url":"https://jvn.jp/en/jp/JVN51464799/index.html","source":"vultures@jpcert.or.jp","tags":["Third Party Advisory"]},{"url":"https://www.softcreate.co.jp/news/detail/210","source":"vultures@jpcert.or.jp","tags":["Vendor Advisory"]},{"url":"https://jvn.jp/en/jp/JVN51464799/index.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]},{"url":"https://www.softcreate.co.jp/news/detail/210","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}