{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T11:03:32.050","vulnerabilities":[{"cve":{"id":"CVE-2022-33183","sourceIdentifier":"sirt@brocade.com","published":"2022-10-25T21:15:46.723","lastModified":"2025-05-07T14:15:31.353","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability in Brocade Fabric OS CLI before Brocade Fabric OS v9.1.0, 9.0.1e, 8.2.3c, 8.2.0cbn5, 7.4.2.j could allow a remote authenticated attacker to perform stack buffer overflow using in “firmwaredownload” and “diagshow” commands."},{"lang":"es","value":"Una vulnerabilidad en Brocade Fabric OS CLI versiones anteriores a Brocade Fabric OS v9.1.0, 9.0.1e, 8.2.3c, 8.2.0cbn5, 7.4.2.j, podría permitir a un atacante remoto autenticado llevar a cabo un desbordamiento del búfer de la pila usando en comandos \"firmwaredownload\" y \"diagshow\""}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*","versionEndExcluding":"7.4.2.j","matchCriteriaId":"8C8BD040-E8F0-4386-B680-19CD1BD381D7"},{"vulnerable":true,"criteria":"cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*","versionStartIncluding":"8.0.0","versionEndExcluding":"8.2.3c","matchCriteriaId":"4F6AC152-58BC-4180-8C73-F1355FC621EC"},{"vulnerable":true,"criteria":"cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*","versionStartIncluding":"9.0.0","versionEndExcluding":"9.0.1e","matchCriteriaId":"903859B2-AA10-4D3C-90A4-0ECE35BF5B72"}]}]}],"references":[{"url":"https://security.netapp.com/advisory/ntap-20230127-0008/","source":"sirt@brocade.com","tags":["Third Party Advisory"]},{"url":"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2022-2085","source":"sirt@brocade.com","tags":["Vendor Advisory"]},{"url":"https://security.netapp.com/advisory/ntap-20230127-0008/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]},{"url":"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2022-2085","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}