{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-23T19:03:05.975","vulnerabilities":[{"cve":{"id":"CVE-2022-32530","sourceIdentifier":"cybersecurity@se.com","published":"2022-06-24T13:15:07.287","lastModified":"2024-11-21T07:06:34.283","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)"},{"lang":"es","value":"Una CWE-668: Se presenta una vulnerabilidad de Exposición de Recursos a Esferas Equivocadas que podría causar que usuarios sean engañados, ocultando alarmas, mostrando la opción de conexión al servidor equivocada o la petición de control equivocada cuando un dispositivo móvil ha sido comprometido por una aplicación maliciosa. Producto afectado: Geo SCADA Mobile (Build 222 y anteriores)"}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L","baseScore":4.8,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":1.3,"impactScore":3.4},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-668"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:geo_scada_mobile:*:*:*:*:*:android:*:*","versionEndExcluding":"2020","matchCriteriaId":"FAF12EB4-7FC7-4F3C-896B-7C4D997A5E07"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:geo_scada_mobile:2020:-:*:*:*:android:*:*","matchCriteriaId":"94B3C2B6-EF85-4813-AD08-34B63BFEA46E"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:geo_scada_mobile:2020:build_222:*:*:*:android:*:*","matchCriteriaId":"8D1B5192-7F9C-4F0D-BBCD-09CFCF4863CC"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}