{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-06T22:16:40.658","vulnerabilities":[{"cve":{"id":"CVE-2022-3156","sourceIdentifier":"PSIRT@rockwellautomation.com","published":"2022-12-27T19:15:10.357","lastModified":"2024-11-21T07:18:56.643","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software.  Users are granted elevated permissions on certain product services when the software is installed. Due to \nthis misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software.\n\n \n\n\n"},{"lang":"es","value":"Existe una vulnerabilidad de ejecución remota de código en el software Rockwell Automation Studio 5000 Logix Emulate. A los usuarios se les otorgan permisos elevados sobre ciertos servicios del producto cuando se instala el software. Debido a esta mala configuración, un usuario malintencionado podría lograr la ejecución remota de código en el software de destino."}],"metrics":{"cvssMetricV31":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","description":[{"lang":"en","value":"CWE-287"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-287"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:studio_5000_logix_emulate:*:*:*:*:*:*:*:*","versionStartIncluding":"20.011","versionEndExcluding":"34.00","matchCriteriaId":"FB9EB8A2-A2F2-45A4-923E-2E40BDF16F76"}]}]}],"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137846","source":"PSIRT@rockwellautomation.com","tags":["Vendor Advisory"]},{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137846","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}