{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-20T07:41:56.285","vulnerabilities":[{"cve":{"id":"CVE-2022-31257","sourceIdentifier":"productcert@siemens.com","published":"2022-07-12T10:15:10.653","lastModified":"2024-11-21T07:04:14.230","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). In case of access to an active user session in an application that is built with an affected version, it’s possible to change that user’s password bypassing password validations within a Mendix application. This could allow to set weak passwords."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en las aplicaciones de Mendix usando Mendix 7 (Todas las versiones anteriores a V7.23.31), las aplicaciones de Mendix usando Mendix 8 (Todas las versiones anteriores a V8.18.18), las aplicaciones de Mendix usando Mendix 9 (Todas las versiones anteriores a V9.14.0), las aplicaciones de Mendix usando Mendix 9 (versión V9.12) (Todas las versiones anteriores a V9.12.2), las aplicaciones de Mendix usando Mendix 9 (versión V9.6) (Todas las versiones anteriores a V9.6.12). En caso de acceder a una sesión de usuario activa en una aplicación construida con una versión afectada, es posible cambiar la contraseña de ese usuario omitiendo las comprobaciones de contraseña dentro de una aplicación Mendix. Esto podría permitir establecer contraseñas débiles"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:P/A:N","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-284"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-Other"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*","versionStartIncluding":"7.0.0","versionEndExcluding":"7.32.31","matchCriteriaId":"A25B23A6-DFBF-46B4-BF0C-5819189EB009"},{"vulnerable":true,"criteria":"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*","versionStartIncluding":"8.0.0","versionEndExcluding":"8.18.18","matchCriteriaId":"8471E2B7-B69D-4D3F-AA7C-B953F28E6D6E"},{"vulnerable":true,"criteria":"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*","versionStartIncluding":"9.6.0","versionEndExcluding":"9.6.12","matchCriteriaId":"DB45CC2F-34B6-4824-8DFC-E571C3F1E873"},{"vulnerable":true,"criteria":"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*","versionStartIncluding":"9.12.0","versionEndExcluding":"9.12.2","matchCriteriaId":"11365A01-2860-4627-8947-1FDB3DC0C454"},{"vulnerable":true,"criteria":"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*","versionStartIncluding":"9.13.0","versionEndExcluding":"9.14.0","matchCriteriaId":"F6942480-6F30-4C74-81DB-ED498BCA42F2"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}