{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T02:52:56.900","vulnerabilities":[{"cve":{"id":"CVE-2022-30473","sourceIdentifier":"cve@mitre.org","published":"2022-05-26T16:15:08.490","lastModified":"2024-11-21T07:02:48.603","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Tenda AC Series Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function form_fast_setting_wifi_set"},{"lang":"es","value":"El router Tenda AC Series AC18 versión V15.03.05.19(6318), presenta una vulnerabilidad de desbordamiento de búfer en la región stack de la memoria en la función form_fast_setting_wifi_set"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*","matchCriteriaId":"3AC468E5-44D1-4B94-B308-C1025DB1BB7B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*","matchCriteriaId":"CF9F8AF9-F921-4348-922B-EE5E6037E7AC"}]}]}],"references":[{"url":"https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/2","source":"cve@mitre.org","tags":["Exploit","Third Party Advisory"]},{"url":"https://github.com/lcyfrank/VulnRepo/tree/master/IoT/Tenda/2","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}}]}