{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T09:40:12.577","vulnerabilities":[{"cve":{"id":"CVE-2022-30232","sourceIdentifier":"cybersecurity@se.com","published":"2022-06-02T23:15:07.443","lastModified":"2024-11-21T07:02:24.360","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)"},{"lang":"es","value":"Una CWE-20: Se presenta una vulnerabilidad de Comprobación de Entrada Inapropiada que podría causar una potencial ejecución de código remota cuando un atacante es capaz de interceptar y modificar una petición en la misma red o presenta acceso de configuración a un dispositivo ION en la red. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","baseScore":8.0,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.1,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","baseScore":6.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-20"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:powerlogic_ion_setup_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.2.22096.01","matchCriteriaId":"B1A4B3A2-BAB3-4C23-99B5-9902786DA40E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:powerlogic_ion_setup:-:*:*:*:*:*:*:*","matchCriteriaId":"0860D069-9B26-437E-A156-61413BECE043"}]}]}],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2022-130-01/","source":"cybersecurity@se.com","tags":["Patch","Vendor Advisory"]},{"url":"https://www.se.com/ww/en/download/document/SEVD-2022-130-01/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}