{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-29T11:35:07.190","vulnerabilities":[{"cve":{"id":"CVE-2022-29831","sourceIdentifier":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","published":"2022-11-25T00:15:10.437","lastModified":"2024-11-21T06:59:46.443","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules."},{"lang":"es","value":"El uso de la vulnerabilidad de contraseña codificada en Mitsubishi Electric Corporation GX Works3 desde la versión 1.015R hasta 1.095Z permite a un atacante remoto no autenticado obtener información sobre el archivo de proyecto para los módulos de CPU de seguridad MELSEC."}],"metrics":{"cvssMetricV31":[{"source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6}]},"weaknesses":[{"source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","type":"Secondary","description":[{"lang":"en","value":"CWE-259"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-798"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*","versionStartIncluding":"1.015r","versionEndIncluding":"1.086q","matchCriteriaId":"56BD062B-0D41-42E2-B9EF-B7FBB514CFF9"},{"vulnerable":true,"criteria":"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*","versionStartIncluding":"1.087r","matchCriteriaId":"C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A"}]}]}],"references":[{"url":"https://jvn.jp/vu/JVNVU97244961","source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05","source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"},{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf","source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","tags":["Mitigation","Vendor Advisory"]},{"url":"https://jvn.jp/vu/JVNVU97244961","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Vendor Advisory"]}]}}]}