{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-19T16:12:51.003","vulnerabilities":[{"cve":{"id":"CVE-2022-28813","sourceIdentifier":"info@cert.vde.com","published":"2022-09-28T14:15:10.513","lastModified":"2026-06-17T04:39:07.313","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of an SQL-injection to gain access to a volatile temporary database with the current states of the device."},{"lang":"es","value":"En Carlo Gavazzi UWP versión 3.0 en múltiples versiones y CPY Car Park Server en versión 2.8.3, un atacante remoto no autenticado podría hacer uso de una inyección SQL para conseguir acceso a una base de datos temporal volátil con los estados actuales del dispositivo"}],"affected":[{"source":"info@cert.vde.com","affectedData":[{"vendor":"Carlo Gavazzi","product":"UWP 3.0 Monitoring Gateway and Controller","versions":[{"version":"8","lessThan":"8.5.0.3","versionType":"custom","status":"affected"}]},{"vendor":"Carlo Gavazzi","product":"UWP 3.0 Monitoring Gateway and Controller – Security Enhanced","versions":[{"version":"8","lessThan":"8.5.0.3","versionType":"custom","status":"affected"}]},{"vendor":"Carlo Gavazzi","product":"UWP 3.0 Monitoring Gateway and Controller – EDP version","versions":[{"version":"8","lessThan":"8.5.0.3","versionType":"custom","status":"affected"}]},{"vendor":"Carlo Gavazzi","product":"CPY Car Park Server","versions":[{"version":"2","lessThan":"2.8.3","versionType":"custom","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"info@cert.vde.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-05-21T14:58:13.461268Z","id":"CVE-2022-28813","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"info@cert.vde.com","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]},{"source":"nvd@nist.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:gavazziautomation:cpy_car_park_server:*:*:*:*:*:*:*:*","versionEndExcluding":"2.8.3","matchCriteriaId":"6E670508-7A94-4A01-9C2B-51E82D5A861F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:gavazziautomation:uwp_3.0_monitoring_gateway_and_controller_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"8.5.0.3","matchCriteriaId":"14B2D9AB-2D19-4AD6-A049-CDB6814CC8D0"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:gavazziautomation:uwp_3.0_monitoring_gateway_and_controller:-:*:*:*:*:*:*:*","matchCriteriaId":"90DBF492-5F3A-4F53-ACFC-59F89470D632"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:gavazziautomation:uwp_3.0_monitoring_gateway_and_controller_firmware:*:*:edp:*:*:*:*:*","versionEndExcluding":"8.5.0.3","matchCriteriaId":"5BFC1445-995C-44F7-BE85-E0C1D462573E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:gavazziautomation:uwp_3.0_monitoring_gateway_and_controller:-:*:edp:*:*:*:*:*","matchCriteriaId":"C7900CB8-560F-4DD7-82B9-8226A8F5F5CC"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:gavazziautomation:uwp_3.0_monitoring_gateway_and_controller_firmware:*:*:security_enhanced:*:*:*:*:*","versionEndExcluding":"8.5.0.3","matchCriteriaId":"F6584CB1-FA0B-468D-AA58-F2D2F33763AA"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:gavazziautomation:uwp_3.0_monitoring_gateway_and_controller:-:*:security_enhanced:*:*:*:*:*","matchCriteriaId":"B29F6465-3533-4B50-B436-4DC4E6F1B361"}]}]}],"references":[{"url":"https://cert.vde.com/en/advisories/VDE-2022-029/","source":"info@cert.vde.com","tags":["Third Party Advisory"]},{"url":"https://cert.vde.com/en/advisories/VDE-2022-029/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}