{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T01:49:04.073","vulnerabilities":[{"cve":{"id":"CVE-2022-27525","sourceIdentifier":"psirt@autodesk.com","published":"2022-04-18T17:15:16.813","lastModified":"2024-11-21T06:55:52.927","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A malicious crafted .dwf or .pct file when consumed through DesignReview.exe application could lead to memory corruption vulnerability by write access violation. This vulnerability in conjunction with other vulnerabilities could lead to code execution in the context of the current process."},{"lang":"es","value":"Un archivo .dwf o .pct malicioso cuando se consume a través de la aplicación DesignReview.exe podría llevar a una vulnerabilidad de corrupción de memoria por violación de acceso de escritura. Esta vulnerabilidad, junto con otras, podría conducir a la ejecución de código en el contexto del proceso actual"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:autodesk:design_review:2011:*:*:*:*:*:*:*","matchCriteriaId":"83CF6CDF-806C-4DC5-B572-C1C2BC2C25F2"},{"vulnerable":true,"criteria":"cpe:2.3:a:autodesk:design_review:2012:*:*:*:*:*:*:*","matchCriteriaId":"2A78B6F8-DF84-4E6C-A247-0F6D2F8CA679"},{"vulnerable":true,"criteria":"cpe:2.3:a:autodesk:design_review:2013:*:*:*:*:*:*:*","matchCriteriaId":"DCD2CA9B-16E1-4BE7-A4E1-A9817A503958"},{"vulnerable":true,"criteria":"cpe:2.3:a:autodesk:design_review:2017:*:*:*:*:*:*:*","matchCriteriaId":"31F2529F-ECF0-4568-BBDC-82B396A52332"},{"vulnerable":true,"criteria":"cpe:2.3:a:autodesk:design_review:2018:-:*:*:*:*:*:*","matchCriteriaId":"213232B9-A40B-436D-A66A-B65C49D59BE6"},{"vulnerable":true,"criteria":"cpe:2.3:a:autodesk:design_review:2018:hotfix:*:*:*:*:*:*","matchCriteriaId":"2D0CF4DC-ACA5-41D0-B28E-CEB5D2C96F71"},{"vulnerable":true,"criteria":"cpe:2.3:a:autodesk:design_review:2018:hotfix2:*:*:*:*:*:*","matchCriteriaId":"84ED1789-A17F-48F7-A152-09D2A5C59254"},{"vulnerable":true,"criteria":"cpe:2.3:a:autodesk:design_review:2018:hotfix3:*:*:*:*:*:*","matchCriteriaId":"74819924-EB63-4BBF-9986-FEF6100EEE15"},{"vulnerable":true,"criteria":"cpe:2.3:a:autodesk:design_review:2018:hotfix4:*:*:*:*:*:*","matchCriteriaId":"100922EF-C773-4798-B352-B16FCAD48F36"}]}]}],"references":[{"url":"https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0004","source":"psirt@autodesk.com","tags":["Vendor Advisory"]},{"url":"https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0004","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}