{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-11T00:12:04.813","vulnerabilities":[{"cve":{"id":"CVE-2022-26507","sourceIdentifier":"cve@mitre.org","published":"2022-04-14T13:15:11.637","lastModified":"2024-11-21T06:54:04.920","vulnStatus":"Modified","cveTags":[{"sourceIdentifier":"cve@mitre.org","tags":["unsupported-when-assigned"]}],"descriptions":[{"lang":"en","value":"A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer"},{"lang":"es","value":"** NO SOPORTADO CUANDO SE ASIGNÓ ** Se presenta un desbordamiento de búfer en la región heap de la memoria en XML Decompression DecodeTreeBlock en AT&amp;T Labs Xmill versión 0.7. Un archivo de entrada diseñado puede conllevar a una ejecución de código remota. Esto no es lo mismo que cualquiera de: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, o CVE-2021-21830. NOTA: Esta vulnerabilidad sólo afecta a productos que ya no son soportados por el mantenedor"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:att:xmill:0.7:*:*:*:*:*:*:*","matchCriteriaId":"4CC987F6-AAFA-4CDE-842D-EA7858A3E7F4"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*","versionEndExcluding":"15.1","matchCriteriaId":"8DCC0C29-32C2-4463-B98F-AB4B56FF5314"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:-:*:*:*:*:*:*","matchCriteriaId":"78F6B1CC-488B-48E8-B96B-77A1894E9E92"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*","versionEndExcluding":"2021","matchCriteriaId":"FAB4A9EC-96A2-424D-A858-162E662EBEFB"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*","matchCriteriaId":"3FFDF36B-30A5-4B35-956C-60DC15CE7EE4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*","matchCriteriaId":"F51A7887-4F1A-428C-9E68-260E7262A678"},{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*","matchCriteriaId":"58BACC54-6609-4DCE-AEEC-A9C2396635A0"},{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*","matchCriteriaId":"FFDF44F3-2514-4CB0-A1A4-87123225B0F1"},{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*","matchCriteriaId":"4F5CDC99-C4C8-43FE-8EA7-65C7EDFD9BA3"},{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*","matchCriteriaId":"DE4172DF-94E3-4AEE-8D6B-9F48DC453B9E"}]}]}],"references":[{"url":"https://Claroty.com","source":"cve@mitre.org","tags":["Not Applicable","Third Party Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02","source":"cve@mitre.org","tags":["Mitigation","Release Notes","Third Party Advisory"]},{"url":"https://Claroty.com","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Not Applicable","Third Party Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Release Notes","Third Party Advisory"]}]}}]}