{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T08:51:45.956","vulnerabilities":[{"cve":{"id":"CVE-2022-25756","sourceIdentifier":"productcert@siemens.com","published":"2022-04-12T09:15:14.837","lastModified":"2024-11-21T06:52:56.657","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, revestido), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, revestido), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, revestido), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, revestido), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, revestido), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, revestido), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, revestido), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, revestido), SCALANCE X307-3 SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, puertos en la parte frontal), SCALANCE XR324-12M (230V, puertos en la parte delantera), SCALANCE XR324-12M (230V, puertos en la parte trasera), SCALANCE XR324-12M (230V, puertos en la parte trasera), SCALANCE XR324-12M (24V, puertos en la parte delantera), SCALANCE XR324-12M (24V, puertos en la parte delantera), SCALANCE XR324-12M (24V, puertos en la parte trasera), SCALANCE XR324-12M (24V, puertos en la parte trasera), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte trasera), SCALANCE XR324-4M PoE (230V, puertos en la parte delantera), SCALANCE XR324-4M PoE (230V, puertos en la parte trasera), SCALANCE XR324-4M PoE (24V, puertos en la parte delantera), SCALANCE XR324-4M PoE (24V, puertos en la parte trasera), SCALANCE XR324-4M PoE TS (24V, puertos en la parte delantera), SIPLUS NET SCALANCE X308-2. El servidor web integrado podría permitir ataques de tipo Cross-Site Scripting (XSS) si los usuarios desprevenidos son engañados para acceder a un enlace malicioso. Esto puede ser usado por un atacante para lanzar una petición maliciosa en el dispositivo afectado"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-80"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"7FB6F150-2662-44AE-8DC1-0B0A426E8352"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*","matchCriteriaId":"C8E97B3B-1808-45D2-97B7-CF31CA6E7A60"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"E9F4071F-1AE2-4FAD-A8CB-1619552101A3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*","matchCriteriaId":"0087A1C6-AA76-4FD6-BAA1-D3190D2A0116"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"4B78CFDF-1B15-4A4B-99D4-8CC5E1867BD1"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*","matchCriteriaId":"880CF41B-B25D-4744-8E8B-C4B131932B1B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"CCB1094D-3F8A-4331-ABB9-46B73F7E008F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*","matchCriteriaId":"804EE08B-75A1-4CF6-9C30-8CF0CDC39658"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"EE21803A-A5CA-482A-ABD2-C9A547831BF6"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*","matchCriteriaId":"55EF0738-C9EF-4E4B-A7E7-ECC1B5F0678A"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"EEBFBB10-35E0-46BB-A937-E9A933C4D5BC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*","matchCriteriaId":"7737F0C2-43FC-4330-88F2-9B08BA5B35D7"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"4C91F6DD-A74C-4310-88AB-63A39D0208BE"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*","matchCriteriaId":"6CCED3E4-38EF-4645-B25C-4F2C3D4E091C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"6B5513D8-59DD-4EE1-B2E8-F800D1DA7BC5"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*","matchCriteriaId":"FE1909FA-C8C6-46BE-83C6-2635D36FE69B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"A11DE626-D744-49A7-93C4-FE2C2AF5245F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*","matchCriteriaId":"6DDBD94D-5312-4A54-AF76-D9DF791C0292"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"DC259CD1-5C79-4491-B375-7A69116F2747"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*","matchCriteriaId":"85153EED-C677-495D-A6BB-72365DE1ED3F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"79918934-7B0B-4032-972E-2347CD33029D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*","matchCriteriaId":"AC54911E-C432-48FA-9551-9644422FFE14"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"00FBD442-84AA-48F3-8AD1-5767FFB2FC3F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*","matchCriteriaId":"3E22C57C-2BD6-4C39-93D2-5D81A58EA6F0"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"E72D4503-5AAE-4C6F-BAE9-FA51701191B1"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*","matchCriteriaId":"DFCCB68C-A58D-4543-A11F-721B01FFBBA4"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"CA2333C8-E9C7-43D8-9EAA-A88ECAAB4236"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*","matchCriteriaId":"7FE3716E-1C0A-4B72-809A-8318E5853FB1"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"7EECD381-262F-4C47-90E1-7B44092C74BD"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*","matchCriteriaId":"8FB34E83-83A3-45C3-B040-D8910971D439"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"36C40232-5696-44CC-B38F-5331A745C760"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*","matchCriteriaId":"CC54880F-CBF4-4772-A4FB-B07D97287D44"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"2F1969E4-CFD6-4AC7-956E-374967F5C406"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*","matchCriteriaId":"B2D400F5-AD80-4536-A99D-793E1560757B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"3ACB931D-C484-42F4-9912-24B44FE97017"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*","matchCriteriaId":"0C632B90-EB11-4A4C-8128-DABBE044B9AF"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"B1EFA152-D29B-4116-A3D2-ACF7A025E053"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*","matchCriteriaId":"6F952542-6B79-4681-A236-15C188AAEB1E"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"935CD21D-0471-4D1F-AF81-B1F996A9EFAB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*","matchCriteriaId":"664D9C76-BC13-4874-939C-A8211DA33903"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"E2C0F1FB-8B5E-448C-A304-FDDCB3DFCDD4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*","matchCriteriaId":"4834A67B-7B0B-4F88-BBFB-25667FD68EC5"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"3E0E1F54-D9EA-4AFB-80EF-0A585EC3C641"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*","matchCriteriaId":"36C9AE74-4683-4ED0-A605-3A6B065C230E"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"DC03DF92-C7A1-4232-AFDF-04B2B50666DB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*","matchCriteriaId":"4356417E-B4CB-45B0-B395-CE9D423FAB44"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.4","matchCriteriaId":"25103533-B9BC-4553-B195-AF5CACAB713B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*","matchCriteriaId":"9C48C944-324B-4390-B9D1-3D0FC3DD5BFD"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf","source":"productcert@siemens.com","tags":["Mitigation","Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Patch","Vendor Advisory"]}]}}]}