{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T15:22:06.990","vulnerabilities":[{"cve":{"id":"CVE-2022-25558","sourceIdentifier":"cve@mitre.org","published":"2022-03-10T17:47:13.727","lastModified":"2024-11-21T06:52:21.553","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function formSetProvince. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ProvinceCode parameter."},{"lang":"es","value":"Se ha detectado que Tenda AX1806 versión v1.0.0.1, contiene un desbordamiento de pila en la función formSetProvince. Esta vulnerabilidad permite a atacantes causar una Denegación de Servicio (DoS) por medio del parámetro ProvinceCode"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","baseScore":7.8,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tenda:ax1806_firmware:1.0.0.1:*:*:*:*:*:*:*","matchCriteriaId":"578F9769-EF24-4B52-83D3-9AA2C91A503D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tenda:ax1806:-:*:*:*:*:*:*:*","matchCriteriaId":"ACA44369-A513-474F-8DD0-A81B598F5B07"}]}]}],"references":[{"url":"https://github.com/sec-bin/IoT-CVE/tree/main/Tenda/AX1806/13","source":"cve@mitre.org","tags":["Exploit","Third Party Advisory"]},{"url":"https://github.com/sec-bin/IoT-CVE/tree/main/Tenda/AX1806/13","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}}]}