{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-15T16:08:11.212","vulnerabilities":[{"cve":{"id":"CVE-2022-24661","sourceIdentifier":"productcert@siemens.com","published":"2022-03-08T12:15:11.677","lastModified":"2024-11-21T06:50:48.887","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2022.1). The starview+.exe contains a memory corruption vulnerability while parsing specially crafted .SCE files. This could allow an attacker to execute code in the context of the current process."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Simcenter STAR-CCM+ Viewer (Todas las versiones anteriores a la versión V2022.1). El starview+.exe contiene una vulnerabilidad de corrupción de memoria al analizar archivos .SCE especialmente diseñados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-119"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simcenter_star-ccm\\+_viewer:*:*:*:*:*:*:*:*","versionEndExcluding":"2022.1","matchCriteriaId":"B1C459A8-8F6A-4DA0-BD39-BE0FF57F95BE"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-166747.pdf","source":"productcert@siemens.com","tags":["Mitigation","Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-166747.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Patch","Vendor Advisory"]}]}}]}