{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-08T02:06:48.247","vulnerabilities":[{"cve":{"id":"CVE-2022-22812","sourceIdentifier":"cybersecurity@se.com","published":"2022-02-09T23:15:19.433","lastModified":"2024-11-21T06:47:29.743","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)"},{"lang":"es","value":"Una CWE-79: Se presenta una vulnerabilidad de Neutralización Inadecuada de Entradas Durante la Generación de Páginas Web (\"Cross-site Scripting\") que podría causar un compromiso de la sesión web cuando un atacante inyecta y luego ejecuta código JavaScript malicioso arbitrario dentro del navegador de destino. Producto afectado: spaceLYnk (versiones V2.6.2 y anteriores), Wiser for KNX (anteriormente homeLYnk) (versiones V2.6.2 y anteriores), fellerLYnk (V2.6.2 y anteriores)"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.6.2","matchCriteriaId":"64C0D5C8-3559-4591-8F88-A9D6E3DFA9E4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*","matchCriteriaId":"F7B2FBBD-C461-47EF-A912-E445C063DED9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.6.2","matchCriteriaId":"BD308EE6-41C3-4D93-A2A5-9D7EFF3A8413"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:wiser_for_knx:-:*:*:*:*:*:*:*","matchCriteriaId":"EAF53585-8B87-4609-991E-30B56B601DEA"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:fellerlynk_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.6.2","matchCriteriaId":"89174639-40D3-4A31-8357-7C497BCF2895"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:fellerlynk:-:*:*:*:*:*:*:*","matchCriteriaId":"FC947F97-7E49-475F-84E6-29D7A6DF50CB"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04","source":"cybersecurity@se.com","tags":["Patch","Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}