{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-24T02:46:43.174","vulnerabilities":[{"cve":{"id":"CVE-2022-22809","sourceIdentifier":"cybersecurity@se.com","published":"2022-02-09T23:15:19.293","lastModified":"2024-11-21T06:47:29.373","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)"},{"lang":"es","value":"Una CWE-306: Se presenta una vulnerabilidad de Falta de Autenticación para la Función Crítica que podría permitir una modificación de las configuraciones táctiles de forma no autorizada cuando un atacante intenta modificar las configuraciones táctiles. Producto afectado: spaceLYnk (versiones V2.6.2 y anteriores), Wiser for KNX (anteriormente homeLYnk) (versiones V2.6.2 y anteriores), fellerLYnk (versiones V2.6.2 y anteriores)"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":1.4}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:P/A:N","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-306"}]},{"source":"nvd@nist.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-306"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.6.2","matchCriteriaId":"64C0D5C8-3559-4591-8F88-A9D6E3DFA9E4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*","matchCriteriaId":"F7B2FBBD-C461-47EF-A912-E445C063DED9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.6.2","matchCriteriaId":"BD308EE6-41C3-4D93-A2A5-9D7EFF3A8413"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:wiser_for_knx:-:*:*:*:*:*:*:*","matchCriteriaId":"EAF53585-8B87-4609-991E-30B56B601DEA"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:fellerlynk_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.6.2","matchCriteriaId":"89174639-40D3-4A31-8357-7C497BCF2895"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:fellerlynk:-:*:*:*:*:*:*:*","matchCriteriaId":"FC947F97-7E49-475F-84E6-29D7A6DF50CB"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04","source":"cybersecurity@se.com","tags":["Patch","Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}