{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T17:31:23.853","vulnerabilities":[{"cve":{"id":"CVE-2022-22732","sourceIdentifier":"cybersecurity@se.com","published":"2023-01-30T23:15:09.753","lastModified":"2024-11-21T06:47:20.603","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)"},{"lang":"es","value":"Existe una vulnerabilidad CWE-668: Exposure of Resource to Wrong Sphere que podría provocar que todos los dominios remotos accedan a los recursos (datos) proporcionados por el servidor cuando un atacante envía una solicitud de recuperación desde un sitio de terceros o un sitio malicioso. Productos afectados: EcoStruxure Power Commission (versiones anteriores a la V2.22)"}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N","baseScore":3.9,"baseSeverity":"LOW","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":1.3,"impactScore":2.5},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-668"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_power_commission:*:*:*:*:*:*:*:*","versionEndExcluding":"2.22","matchCriteriaId":"E59BB009-9A61-46F7-BC46-44B4EC678EE4"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf","source":"cybersecurity@se.com","tags":["Patch","Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}