{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T08:51:04.917","vulnerabilities":[{"cve":{"id":"CVE-2022-1522","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2022-09-06T23:15:08.307","lastModified":"2024-11-21T06:40:53.750","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics."},{"lang":"es","value":"Cognex 3D-A1000 Dimensioning System en versión de firmware 1.0.3 (3354) y anteriores, es vulnerable a CWE-117: Neutralización Inadecuada de la Salida de los Registros, que permite a un atacante crear registros falsos que muestren que la contraseña ha sido cambiada cuando no es así, complicando los análisis forenses."}],"metrics":{"cvssMetricV31":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":1.4},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":1.4}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-117"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cognex:3d-a1000_dimensioning_system_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"1.0.3\\(3354\\)","matchCriteriaId":"BE25BB24-A1BE-4904-935B-61E84CAAFD81"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cognex:3d-a1000_dimensioning_system:-:*:*:*:*:*:*:*","matchCriteriaId":"01F624C6-079A-40BB-BA07-3441A6934850"}]}]}],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}