{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T10:42:05.017","vulnerabilities":[{"cve":{"id":"CVE-2022-1368","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2022-09-06T23:15:08.240","lastModified":"2024-11-21T06:40:35.250","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account."},{"lang":"es","value":"Cognex 3D-A1000 Dimensioning System en versión de firmware 1.0.3 (3354) y anteriores, es vulnerable a CWE-306: Una Falta de Autentificación para la Función Crítica, que permite que usuarios no autorizados cambien la contraseña de la cuenta del operador por medio de comandos del servidor web mediante la monitorización de las comunicaciones del socket web desde una sesión no autenticada. Esto podría permitir a un atacante escalar privilegios hasta igualar los de la cuenta comprometida.\n"}],"metrics":{"cvssMetricV31":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-306"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cognex:3d-a1000_dimensioning_system_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"1.0.3\\(3354\\)","matchCriteriaId":"BE25BB24-A1BE-4904-935B-61E84CAAFD81"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cognex:3d-a1000_dimensioning_system:-:*:*:*:*:*:*:*","matchCriteriaId":"01F624C6-079A-40BB-BA07-3441A6934850"}]}]}],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}