{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-29T19:53:05.304","vulnerabilities":[{"cve":{"id":"CVE-2021-44432","sourceIdentifier":"productcert@siemens.com","published":"2021-12-14T12:15:11.073","lastModified":"2024-11-21T06:30:57.993","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to stack based buffer overflow while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14845)"},{"lang":"es","value":"Se ha identificado una vulnerabilidad en JT Utilities (Todas las versiones anteriores a V13.1.1.0), JTTK (Todas las versiones anteriores a V11.1.1.0). La biblioteca JTTK de los productos afectados es vulnerable al desbordamiento del búfer en la región stack de la memoria al analizar archivos JT especialmente diseñados. Un atacante podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual. (ZDI-CAN-14845)"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:jt_open_toolkit:*:*:*:*:*:*:*:*","versionEndExcluding":"11.1.1.0","matchCriteriaId":"8E5FA782-E074-4406-ACA6-788DD24327C7"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:jt_utilities:*:*:*:*:*:*:*:*","versionEndExcluding":"13.1.1.0","matchCriteriaId":"A46E8F39-E213-48F4-8355-E34118668B49"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}