{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-20T21:47:25.780","vulnerabilities":[{"cve":{"id":"CVE-2021-44165","sourceIdentifier":"productcert@siemens.com","published":"2021-12-14T12:15:10.923","lastModified":"2024-11-21T06:30:28.937","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en POWER METER SICAM Q100 (Todas las versiones anteriores a V2.41), POWER METER SICAM Q100 (Todas las versiones anteriores a V2.41), POWER METER SICAM Q100 (Todas las versiones anteriores a V2.41), POWER METER SICAM Q100 (Todas las versiones anteriores a V2.41). El firmware afectado contiene una vulnerabilidad de desbordamiento de búfer en la aplicación web que podría permitir a un atacante remoto con privilegios de ingeniero o administrador realizar potencialmente una ejecución de código remota"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C","baseScore":9.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8.0,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:7kg9501-0aa01-2aa1_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.41","matchCriteriaId":"96EDF0C8-91BF-48C2-8FDC-C3AFBC8878D0"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:7kg9501-0aa01-2aa1:-:*:*:*:*:*:*:*","matchCriteriaId":"275E9296-AACA-4F3B-B8FA-D52A59E729DE"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:7kg9501-0aa31-0aa1_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.41","matchCriteriaId":"B100E1D3-4D10-4066-9067-799076DD6643"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:7kg9501-0aa31-0aa1:-:*:*:*:*:*:*:*","matchCriteriaId":"B09F87C0-1A7D-43F6-A02F-D808C880FF74"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:7kg9501-0aa31-2aa1_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.41","matchCriteriaId":"27616240-C04A-4F45-8A6D-B8044242CF5C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:7kg9501-0aa31-2aa1:-:*:*:*:*:*:*:*","matchCriteriaId":"DC260D4F-53BD-433C-AE8F-FA2FA47BC921"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:7kg9501-0aa01-0aa1_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.41","matchCriteriaId":"AD0414B9-4EF2-4486-A2BA-926CD0A1D23A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:7kg9501-0aa01-0aa1:-:*:*:*:*:*:*:*","matchCriteriaId":"632E89F3-80E7-4E2F-A3D3-0A6183F4A444"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}