{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-25T14:33:03.673","vulnerabilities":[{"cve":{"id":"CVE-2021-43587","sourceIdentifier":"security_alert@emc.com","published":"2021-12-21T17:15:08.357","lastModified":"2026-06-17T04:11:10.790","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges."},{"lang":"es","value":"Dell PowerPath Management Appliance, versiones 3.2, 3.1, 3.0 P01, 3.0 y 2.6, usan una clave criptográfica embebida. Un usuario local malicioso con privilegios elevados podría explotar esta vulnerabilidad para conseguir acceso a los secretos y elevarse para conseguir privilegios superiores"}],"affected":[{"source":"security_alert@emc.com","affectedData":[{"vendor":"Dell","product":"PowerPath Management Appliance","versions":[{"version":"unspecified","lessThan":"3.2 P01","versionType":"custom","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","baseScore":8.2,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.5,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":6.7,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","baseScore":7.2,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":3.9,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"security_alert@emc.com","type":"Secondary","description":[{"lang":"en","value":"CWE-321"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:dell:powerpath_management_appliance:2.6:*:*:*:*:*:*:*","matchCriteriaId":"52816B9C-22F2-441E-91F1-5259597B74A5"},{"vulnerable":true,"criteria":"cpe:2.3:a:dell:powerpath_management_appliance:3.0:-:*:*:*:*:*:*","matchCriteriaId":"1FEE04FA-1675-4981-ABBC-6B897F262D66"},{"vulnerable":true,"criteria":"cpe:2.3:a:dell:powerpath_management_appliance:3.0:patch_01:*:*:*:*:*:*","matchCriteriaId":"365876FA-46CC-4AD7-BD47-DC81526B543F"},{"vulnerable":true,"criteria":"cpe:2.3:a:dell:powerpath_management_appliance:3.1:*:*:*:*:*:*:*","matchCriteriaId":"FC22B1B0-E9A4-44F7-BAA3-7F3F592448FE"},{"vulnerable":true,"criteria":"cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*","matchCriteriaId":"D92273A9-3C81-4082-9550-DC1497AEDF39"}]}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260","source":"security_alert@emc.com","tags":["Patch","Vendor Advisory"]},{"url":"https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}