{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T03:24:01.807","vulnerabilities":[{"cve":{"id":"CVE-2021-40355","sourceIdentifier":"productcert@siemens.com","published":"2021-09-14T11:15:26.743","lastModified":"2024-11-21T06:23:56.333","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The affected application contains Insecure Direct Object Reference (IDOR) vulnerability that allows an attacker to use user-supplied input to access objects directly."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Teamcenter versión V12.4 (Todas las versiones anteriores a V12.4.0.8), Teamcenter versión V13.0 (Todas las versiones anteriores a V13.0.0.7), Teamcenter versión V13.1 (Todas las versiones anteriores a V13.1.0.5), Teamcenter versión V13.2 (Todas las versiones anteriores a 13.2.0.2). La aplicación afectada contiene una vulnerabilidad de Direct Object Reference (IDOR) que permite a un atacante usar la entrada suministrada por el usuario para acceder directamente a los objetos"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","baseScore":6.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-639"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"12.4.0","versionEndExcluding":"12.4.0.8","matchCriteriaId":"13870B36-3683-4B71-9322-CE26AB6724D3"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"13.0.0","versionEndExcluding":"13.0.0.7","matchCriteriaId":"0AE45246-C5C8-42C4-807F-0C6D34C1200B"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"13.1.0","versionEndExcluding":"13.1.0.5","matchCriteriaId":"A1360B8D-7874-413B-A6F0-6ACEA39236A2"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"13.2.0","versionEndExcluding":"13.2.0.2","matchCriteriaId":"4339F831-9FD8-4FD3-B874-F88F77B8081B"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-987403.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-987403.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}