{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T13:31:29.003","vulnerabilities":[{"cve":{"id":"CVE-2021-37203","sourceIdentifier":"productcert@siemens.com","published":"2021-09-14T11:15:26.473","lastModified":"2024-11-21T06:14:51.227","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). El archivo plmxmlAdapterIFC.dll contiene una lectura fuera de límites al analizar los archivos IFC suministrados por el usuario, lo que podría dar lugar a una lectura más allá del final de un búfer asignado. Esto podría permitir a un atacante causar una condición de denegación de servicio o leer información sensible de ubicaciones de memoria"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.2}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:N/A:P","baseScore":5.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-125"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:nx_1980:*:*:*:*:*:*:*:*","versionEndExcluding":"1984","matchCriteriaId":"D3A09766-0171-4DDA-9BF9-D379DA134571"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*","versionEndExcluding":"se2021","matchCriteriaId":"576A303A-66CA-4694-AA54-9EB0137C24F1"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*","matchCriteriaId":"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*","matchCriteriaId":"49F5649A-349C-42C6-AFFF-CEE1ABC14E67"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*","matchCriteriaId":"756343AA-DB57-40F7-94FA-84BFCDEB6159"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*","matchCriteriaId":"36B0DD28-653E-4069-AB5A-38F8EFEB36CA"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*","matchCriteriaId":"82090774-D894-41C8-82F1-A48A8707E9BB"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*","matchCriteriaId":"BD346D22-9B5D-4A50-94E2-1F5C8D391EC3"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*","matchCriteriaId":"1466AEE0-4A5C-4E2D-80B8-43680F60FC31"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*","matchCriteriaId":"A4173D09-C317-45FF-ABA4-39E5592862F8"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}