{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T04:41:25.613","vulnerabilities":[{"cve":{"id":"CVE-2021-37202","sourceIdentifier":"productcert@siemens.com","published":"2021-09-14T11:15:26.397","lastModified":"2024-11-21T06:14:51.100","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). El adaptador IFC de la aplicación afectada contiene una vulnerabilidad de uso después de libre que podría activarse mientras se analizan los archivos IFC suministrados por el usuario. Un atacante podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-416"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:nx_1980:*:*:*:*:*:*:*:*","versionEndExcluding":"1984","matchCriteriaId":"D3A09766-0171-4DDA-9BF9-D379DA134571"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*","versionEndExcluding":"se2021","matchCriteriaId":"576A303A-66CA-4694-AA54-9EB0137C24F1"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*","matchCriteriaId":"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*","matchCriteriaId":"49F5649A-349C-42C6-AFFF-CEE1ABC14E67"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*","matchCriteriaId":"756343AA-DB57-40F7-94FA-84BFCDEB6159"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*","matchCriteriaId":"36B0DD28-653E-4069-AB5A-38F8EFEB36CA"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*","matchCriteriaId":"82090774-D894-41C8-82F1-A48A8707E9BB"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*","matchCriteriaId":"BD346D22-9B5D-4A50-94E2-1F5C8D391EC3"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*","matchCriteriaId":"1466AEE0-4A5C-4E2D-80B8-43680F60FC31"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*","matchCriteriaId":"A4173D09-C317-45FF-ABA4-39E5592862F8"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}