{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T22:42:14.916","vulnerabilities":[{"cve":{"id":"CVE-2021-36341","sourceIdentifier":"security_alert@emc.com","published":"2021-12-21T17:15:08.253","lastModified":"2024-11-21T06:13:33.400","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Dell Wyse Device Agent version 14.5.4.1 and below contain a sensitive data exposure vulnerability. A local authenticated user with low privileges could potentially exploit this vulnerability in order to access sensitive information."},{"lang":"es","value":"Dell Wyse Device Agent versión 14.5.4.1 y anteriores, contienen una vulnerabilidad de exposición de datos confidenciales. Un usuario local autenticado con bajos privilegios podría explotar potencialmente esta vulnerabilidad para acceder a información confidencial"}],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","baseScore":5.5,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":1.8,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","baseScore":5.5,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":1.8,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:N/A:N","baseScore":2.1,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":3.9,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"security_alert@emc.com","type":"Secondary","description":[{"lang":"en","value":"CWE-200"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:dell:wyse_device_agent:*:*:*:*:*:*:*:*","versionEndIncluding":"14.5.4.1","matchCriteriaId":"EB5A9FA2-249E-4F7D-A27F-33C47CDD715C"}]}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000193151","source":"security_alert@emc.com","tags":["Patch","Vendor Advisory"]},{"url":"https://www.dell.com/support/kbdoc/en-us/000193151","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}