{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-10T11:34:32.702","vulnerabilities":[{"cve":{"id":"CVE-2021-33841","sourceIdentifier":"cve-coordination@incibe.es","published":"2021-06-09T12:15:07.893","lastModified":"2024-11-21T06:09:40.470","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges."},{"lang":"es","value":"Un dispositivo SGE-PLC1000, en su versión de firmware 0.9.2b, no maneja algunas peticiónes correctamente, permitiendo a un atacante remoto inyectar código en el sistema operativo con máximos privilegios"}],"metrics":{"cvssMetricV31":[{"source":"cve-coordination@incibe.es","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","baseScore":10.0,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cve-coordination@incibe.es","type":"Secondary","description":[{"lang":"en","value":"CWE-78"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:circutor:sge-plc1000_firmware:0.9.2b:*:*:*:*:*:*:*","matchCriteriaId":"5D6B02E0-DE36-45F5-AD3D-908E30548661"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*","matchCriteriaId":"FFF41215-1018-42DD-9A7E-BBC2E5B4522D"}]}]}],"references":[{"url":"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-os-command-injection","source":"cve-coordination@incibe.es"},{"url":"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-os-command-injection","source":"af854a3a-2127-422b-91ae-364da2661108"}]}}]}